Countertop Tabletop Sterilizers. Fast Table top Countertop Sterilizers. Eye Surgical Cassettes Surgical Instruments Tabletop Sterilizers Statim 5000.
Tabletop Countertop Tabletop Countertop
Tabletop Countertop Tabletop Countertop
Countertop Tabletop Sterilizers.  Countertop Tabletop Sterilizers.  Countertop Tabletop Sterilizers.
Statim Tabletop Sterilizer
Statim 5000 Statim 2000
Tabletop Countertop Sterilizer Cleaning instruments prior to using statim:
Before sterilization or high-level disinfection, instruments should be cleaned so that any debris is removed. Cleaning is a prerequisite to sterilization of eye & dental surgical instruments. Combination or all-in-one enzymatic based cleaning concentrate solutions facilitate effective instrument cleaning. Heavy-duty gloves should be worn for handling contaminated instruments. Instruments should soak in water or disinfectant/detergent as soon as possible after use to prevent drying of debris. If the instruments cannot be cleaned soon after use, the application of a ‘combination’ or all-in-one enzymatic foam spray will maintain hydration, prevent encrustation, prevent corrosion, and facilitate cleaning.
Statim 5000 Statim 2000 Sterilizers Tabletop Countertop Sterilizers Tabletop Countertop
Tabletop Countertop Autoclave Sterilizer Automated cleaning prior to using statim:
Washer Decontaminators/Disinfectors may be used to reduce direct handling of contaminated instruments. Automated cleaning will reduce overall costs and facilitate a more rapid turnaround of instruments. Washers provide thorough surface cleaning and flushing inside working channels to eliminate the manual cleaning of lumens and working channels. This will ensure that instruments are consistently clean inside and out, thereby reducing the costs and avoiding the worker risks associated with manual cleaning. New design Washer Decontaminators, such as the M3 Washer Decontaminator, will eliminate costly manual cleaning and are available in compact countertop or undercounter models.
Statim 5000 Statim 2000
Tabletop Countertop Sterilizer
Preventing corrosion of surgical instruments:
Using rust inhibitors or an all-in-one enzymatic based cleaning concentrate will protect instruments from corrosion that may result from autoclaving. Thorough rinsing is important to prevent spotting, stains, and accumulation of potentially toxic contaminants. Automated Washers tend to render higher quality instrument care and longer useable instrument life.
Statim 5000 Statim 2000 Sterilizers Tabletop Countertop Sterilizers Tabletop Countertop
Tabletop Countertop Autoclave Sterilizer when to sterilize or disinfect surgical instruments:
According to the CDC- Centers for Disease Control and Prevention, eye & dental instruments are classified into three categories depending on the risk of transmitting infection. The classifications of critical, semi-critical and non-critical are based on the following criteria:
Statim 5000 Statim 2000 Tabletop Countertop Sterilizer and Critical surgical instruments are those used to penetrate soft tissue or bone and should be sterilized after each use. Sterilization is achieved by steam under pressure (autoclaving), dry heat, or heat/chemical vapor. Critical instruments include forceps, scalpels, bone chisels, scalers, and burs.
Statim 5000 Statim 2000 Sterilizers Tabletop Countertop Sterilizers Tabletop Countertop
Tabletop Countertop Autoclave Sterilizer
Semi-critical surgical instruments are those that do not penetrate soft tissues or bone but contact oral tissues, such as mirrors and amalgam condensers. These devices should also be sterilized after each use. In some cases, however, sterilization is not feasible and, therefore, high-level disinfection is appropriate. A high-level disinfectant is registered with the U.S. Environmental Protection Agency (EPA) as a "sterilant/disinfectant" and must be labeled as such.
Statim 5000 Statim 2000 Tabletop Countertop Sterilizer and non-critical surgical instruments are those that come into contact only with intact skin such as external components of X-ray heads. Such devices have a relatively low risk of transmitting infection and, therefore, may be reprocessed between patients by intermediate-level or low-level disinfection. An intermediate-level disinfectant is EPA-registered as a "hospital disinfectant" and will be labeled for "tuberculocidal" activity (e.g., phenolics, iodophors, and chlorine-containing compounds). A low-level disinfectant is EPA-registered as a "hospital disinfectant" but is not labeled for "tuberculocidal" activity (e.g., quaternary ammonium compounds).
All critical and semi-critical dental & eye instruments that are heat-stable should be sterilized after each use by steam under pressure (autoclaving), dry heat, or chemical vapor.
Statim 5000 Statim 2000 Tabletop Countertop Autoclave Sterilizers
Tabletop Countertop Autoclave Sterilizer
Packaging prior to using Statim:
Packaging rinsed and dried instruments before sterilization protects them from contamination after they are removed from the sterilizer and during transport chair side or to storage.
Sterilization is recommended for all high-speed dental & eye hand pieces, low-speed hand piece components used intra-orally, and reusable prophylaxis angles. It is important to follow the manufacturers’ instructions for cleaning, lubrication, and sterilization procedures to ensure the effectiveness of the sterilization process and the longevity of these instruments. High-speed and low-speed hand pieces produced today are heat-tolerant, and many older heat-sensitive models can be retrofitted with heat-stable components.
Validation of Statim 5000 Statim 2000  Tabletop Countertop Sterilizer cycles:
Proper functioning of sterilization cycles should be verified by periodic use of spore tests called biologic indicators. Biologic indicators consist of highly resistant bacterial spores of Bacillus stearothermophilus (used to monitor steam and unsaturated chemical vapor sterilizers) or Bacillus subtilis (used for monitoring the dry heat sterilizer). Chemical indicators (in the form of tape, strips, tabs and special markings on packaging material) indicate exposure to heat. Heat-sensitive chemical indicators that change color after exposure to heat do not guarantee sterilization, but may be used on the outside of each pack to identify those that have been processed through the heating cycle, or in the center of either a load of unwrapped instruments or in each multiple instrument pack.
Statim 5000 Statim 2000 Tabletop Countertop Sterilizer and Liquid chemical germicides and neutral pH cleaners:
In all eye surgery and dental surgery [and other health-care settings], indications for the use of liquid chemical germicides to sterilize instruments (i.e., "cold sterilization") are limited. For heat-sensitive instruments, this procedure may require up to 10 hours of exposure to a liquid chemical agent registered with the EPA as a "sterilant/disinfectant." Instruments sterilized in this manner should be rinsed very carefully with sterile water to thoroughly remove the toxic agents, dried, and placed in a sterile container (if not used immediately). Care must be taken when using liquid chemical germicides due to their carcinogenic nature are their capacity to damage lung and nasal tissues. Neutral pH cleaning concentrates are safe to use and will effectively remove contaminated debris. Neutral pH cleaning concentrates will render instruments that are clean, safe to handle, and will effectively provide the prerequisite for sterilization.
Tabletop Countertop Autoclave Sterilizer
Questions and Answers
Tabletop Countertop Autoclave Sterilizer :
What type of water do I use with Statim 5000 tabletop sterilizer or Statim 2000 tabletop sterilizer [autoclaves] ?
A: Always use steam distilled water in the STATIM tabletop sterilizer Cassette. Other water sources will damage the unit and void the warranty.
Tabletop Countertop Autoclave Sterilizer :
How do I test the quality of distilled water to be used in a  tabletop sterilizer ?
A: If purchasing distilled water, SciCan recommends using a water conductivity tester (SciCan part no. 01-103139S) to check for impurities. If you would like to produce your own distilled water, take a look at SciCan's water distiller product offering.
Tabletop Countertop Autoclave Sterilizer :
How do I prepare instruments for use with Statim 5000 tabletop sterilizer or Statim 2000 tabletop sterilizer [Autoclaves] ?
A: Thoroughly wash, rinse, and dry all instruments before inserting into the Statim.
Tabletop Countertop Autoclave Sterilizer :
How often do I clean the interior and exterior of the cassette for use with Statim 5000 tabletop sterilizer or Statim 2000 tabletop sterilizer [Autoclaves] ?
A: Keeping the Statim tabletop sterilizer cassette clean is good clinical practice. The interior surface of the cassette should be cleaned at least once a week with a mild dishwashing soap. (For instructions, see the Statim Operators Manual). To promote quick drying, we recommend spraying the cassette lid and tray with Stat-dri after each cleaning. After spraying, let the cassette lid and tray dry completely.
Q: How do I lubricate the Statim 5000 tabletop sterilizer or Statim 2000 tabletop sterilizer rubber cassette seal?
A: Lubricate the rubber cassette seal with a mild liquid soap. In a busy practice, this should be done 1-2 times per week.
Q: Tabletop Countertop Sterilizer: What do I do if steam or a puddle of water is detected during or after a tabletop sterilizer cycle?
A: If steam or a puddle of water is detected during or after a cycle, check the cassette seal. This problem may be corrected by doing the following:
a) reseating the seal
b) re-lubricating the tabletop sterilizer seal and probe holes
c) cleaning the outside edge of the tray
Q: Tabletop Countertop Sterilizer: What if I receive an error code when using the Statim 5000 tabletop sterilizer or Statim 2000 tabletop sterilizer ?
A: If the LCD displays a NOT STERILE message, note the error code and consult your tabletop sterilizer Operators Manual.
Q: Tabletop Countertop Sterilizer: Do I need to ensure that the Statim 5000 table top sterilizer or Statim 2000 tabletop sterilizer is level before operating ?
A: Yes. Before operating your Statim 5000 tabletop sterilizer or Statim 2000 tabletop sterilizer [autoclave], make sure it rests on a flat and level surface. If you are uncertain, the level indicator on the front panel and leveler feet underneath the tabletop sterilizer will help you correct any problems. (Align the bubble in the level indicator to the right front quadrant of the target.)
Q: What do I do if my Statim 5000 tabletop sterilizer or Statim 2000 table top sterilizer has not been run for several days ?
A: If you do not operate your Statim 5000 tabletop sterilizer or Statim 2000 tabletop sterilizer [autoclave] for several days, drain the reservoir.
Q: Tabletop Countertop Sterilizer: How should I drain the tabletop sterilizer reservoir ?
A: To empty the reservoir, use the drain tube. If your Statim 5000 table top sterilizer or Statim 2000 tabletop sterilizer does not have a drain tube, a hand pump will suffice. Except when filling or emptying the reservoir, keep the reservoir cap securely fastened at all times.
Q: Tabletop Countertop Sterilizer: What should I do if the Statim 5000 tabletop sterilizer or Statim 2000 tabletop sterilizer is on, but not in use?
A: If your Statim 5000 tabletop sterilizer or Statim 2000 table top sterilizer is powered ON but not in use, pull the cassette 1-2cm out of the unit. This will make the unit inactive until the cassette is reinserted and will prolong the life of your unit.
Q: How do I recognize whether my tabletop sterilizer filter needs replacement ?
A: Monitor the white air filter at the back of the unit. A dirty tabletop sterilizer filter will cause poor drying. If the filter has turned gray, it is in need of replacement (see the maintenance section of the Statim 5000 tabletop sterilizer or Statim 2000 tabletop sterilizer Operator's Manual).
Q: How do I transport my Statim 5000 tabletop sterilizer or Statim 2000 table top sterilizer ?
A: Whenever you need to transport your Statim, make sure you empty the water reservoir and screw-in the feet. Repack your Statim 5000 tabletop sterilizer or Statim 2000 tabletop sterilizer in the original packing materials to reduce any damage.
Contact us for product information and pricing. 
HYDRIM L110W   
Countertop Instrument Washer 
HYDRIM C51W     
Tabletop Instrument Washer 
Surgical Instrument Washers  
CARDINAL Surgical Instrument Detergents  
Contact us for product information and pricing.
Tabletop Sterilizer for Eye Surgical Instruments.
Tabletop Sterilizer Autoclaves for Surgical Instruments.
Cassettes for Eye Surgical Instrument Sterilizers.
Tabletop Countertop Sterilizers
Contact us for product information and pricing.
Countertop Tabletop Sterilizers.  Countertop Tabletop Sterilizers.  Countertop Tabletop Sterilizers.
Countertop Tabletop Sterilizers.  Countertop Tabletop Sterilizers.  Countertop Tabletop Sterilizers.
Countertop Tabletop Sterilizers.  Countertop Tabletop Sterilizers.  Countertop Tabletop Sterilizers.
Tabletop Countertop Tabletop Countertop
Countertop Tabletop Sterilizers. Countertop Tabletop Sterilizers.  Countertop Tabletop Sterilizers.
Sterilize between case. safely and effectively.
Statim 5000 9 minute sterilizer cycles are easy to operate.
Tabletop Countertop for Eye Surgical Instruments.
Tabletop Countertop Surgical Instrument Washers Click Here.
Bravo 17 Sterilizer
Tabletop Sterilizer
sterilize between procedures.
Statim 5000
Tabletop Sterilizer
is fully automatic and easy to operate.
Countertop Surgical Instrument Sterilizer 
Tabletop Surgical Instrument Sterilizer 
Contact us for product information and pricing.
Surgical Instrument Cleaning 
that is: Non Irritating, Biodegradable, Neutral pH, and Phosphate free. 
Recognized as the worldwide leader in Surgical Instrument Cleaning and Care products, the ONEStep™ Team has released the easy FOAM-it Surgical Instrument Pre-wash Cleaner, delivering the most effective 4 Enzyme Detergent surgical instrument cleaning power.
4 Enzyme Surgical Instrument Detergents.
Enzyme Detergent Lubricant Surgical Instrument Cleaning
ONEStep product for cleaning surgical instruments cleaner, the 4 Enzyme Detergent. Four Enzymes are necessary to remove all forms of proteinaceous surgical instrument bioburden. ONEStep delivers 4 Enzyme Detergents, stain removers, and a surgical instrument lubricant.
Surgical Instrument Cleaning
Surgical Instrument Lubricant, 4 enzyme cleaners, detergents, and surface cleaning agents with conditioners for fast, and cost effective  cleaning.
Surgical Instrument Cleaner and Conditioning
Enzyme Detergent Surgical Instrument Cleaner
concentrated
4 Enzyme Surgical Instrument Detergents cleaning power. 
ONE gallon of the ergo-Logistics
Surgical Instrument Cleaner delivers
512 gallons of
Surgical Instrument Cleaning power.
The dilution rate of .25 to .5 ounces per gallon of water delivers high level Surgical Instrument Cleaning with Conditioning.
Sterilizers Tabletop Countertop Sterilizers Tabletop Countertop
Sterilizers Tabletop Countertop Sterilizers Tabletop Countertop
Statim 5000
Bravo 17
Tabletop Sterilizers
Countertop Sterilizers
Bravo 17 sterilizer, Bravo 17v, tabletop sterilizer, Bravo 21v, tabletop sterilizers, countertop sterilizers,
Bravo 17 sterilizer, Bravo 17v, tabletop sterilizer, Bravo 21v, tabletop sterilizers, countertop sterilizers,
Bravo 17 sterilizer, Bravo 17v, tabletop sterilizer, Bravo 21v, tabletop sterilizers, countertop sterilizers,